Welcome | Core Facilities- nitrile gloves hydrofluoric acid melting point charts ,Hydrofluoric acid (HF) is a highly corrosive liquid and is a contact poison. It should be handled with extreme care (i.e., beyond what is generally required to handle other mineral acids). Owing to its low dissociation constant, HF as a neutral lipid-soluble molecule penetrates tissue …CHEMICAL COMPATIBILITY CHART - Bal Seal Engineering3.1.2 Chemical Compatibility Guide for Nitrile (Buna N) ... These tables list the chemical compatibility chart of various elastomer materials commonly used for o-ring. This ... Hydrochloric Acid (2) Hydrocyanic Acid (4) Hydrofluoric Acid (0) Hydrogen Gas (4) Hydrogen Peroxide (0) Hydroquinone (0) Iodine (3) Iso Octane (4) Isobutyl Alcohol (4 ...



Standard Operating Procedure - UCSB

Sep 12, 2012·Dispose of inner nitrile gloves after use as hazardous waste. Wash hands thoroughly with warm water and soap. NOTE: Consult with your preferred glove manufacturer to ensure that the gloves you plan on using are compatible with Hydrofluoric acid. Refer to glove selection chart …

Safety Data Sheet

Safety Data Sheet MSD-221 Page 1 of 2 05/13/2020 1. Product And Company Identification Product Identifier: PIG Hydrofluoric Acid Neutralizing Loose Absorbent (MSD-221) General Use: PIG Hydrofluoric Acid Neutralizing Loose Absorbent is a loose absorbent that will neutralize, absorb and

Hydrofluoric Acid - University of California, Berkeley

least 5 minutes. Remove all contaminated clothing. Wearing compatible gloves (such as nitrile glove), massage calcium gluconate gel into the affected area. Re-apply every 15 minutes. Call 911 to request assistance and/or emergency transport if needed. Note: Hydrofluoric acid exposure is often treated with calcium gluconate, a source of Ca2+ that

HYDROFLUORIC ACID SAFETY GUIDELINES

HYDROFLUORIC ACID SAFETY GUIDELINES Hydrofluoric acid (HF) is an extremely corrosive substances used in the production of organic or inorganic ... Melting point -83,36°C Vapor pressure 13,3 kPa at -28,2°C 53,3 kPa at 2,5°C ... Glove compatibility chart for Hydrofluoric Acid 48% E = excellent, G = good, F = fair 5. Storage, Spill and Waste ...

Safety Data Sheet

Safety Data Sheet MSD-197 Page 1 of 2 04/30/2020 1. Product And Company Identification Product Identifier: PIG Hydrofluoric Acid Neutralizer (MSD-197) General Use: PIG Hydrofluoric Acid Neutralizer is designed to safely neutralize hydrofluoric acid spills into inorganic salts and

Chemical Compatibility Database from Cole-Parmer

The information in this chart has been supplied to Cole-Parmer by other reputable sources and is to be used ONLY as a guide in selecting equipment for appropriate chemical compatibility. Before permanent installation, test the equipment with the chemicals and under the specific conditions of your application.

HYDROFLUORIC ACID SAFETY GUIDELINES

HYDROFLUORIC ACID SAFETY GUIDELINES Hydrofluoric acid (HF) is an extremely corrosive substances used in the production of organic or inorganic ... Melting point -83,36°C Vapor pressure 13,3 kPa at -28,2°C 53,3 kPa at 2,5°C ... Glove compatibility chart for Hydrofluoric Acid 48% E = excellent, G = good, F = fair 5. Storage, Spill and Waste ...

Gloves - Florida State University

• Butyl gloves are made of a synthetic rubber and protect against a wide variety of chemicals, such as peroxide, rocket fuels, highly corrosive acids (nitric acid, sulfuric acid, hydrofluoric acid and red-fuming nitric acid), strong bases, alcohols, aldehydes, ketones, esters and nitro compounds.

Material Safety Data Sheet

Nov 26, 2012·Hydrofluoric Acid, 40% MSDS Section 1: Chemical Product and Company Identification ... Be sure to use an approved/certified respirator or equivalent. Gloves (impervious - neoprene, nitrile). Impervious Boots. Personal Protection in Case of a Large Spill: Splash goggles. Full suit (impervious). Vapor respirator. ... Melting Point: <-36.111°C ...

Arizona State University | Ranked #1 for innovation in the ...

Wearing compatible gloves, massage calcium gluconate gel into the affected area. Re-apply every 15 minutes until medical help arrives. Note: Hydrofluoric acid exposure is often treated with calcium gluconate, a source of Ca2+ that sequesters the fluoride ions.

Standard Operating Procedure

*Inner Butyl Viton gloves can be reused carefully (i.e., without touching the outer surface of the gloves). Wash hands thoroughly with warm water and soap. NOTE: Consult with your preferred glove manufacturer to ensure that the gloves you plan on using are compatible with Hydrofluoric acid.. Refer to glove selection chart from the links below:

ANU Policy Library - Procedure - Hydrofluoric acid handling

Procedure: Hydrofluoric acid handling Purpose. This procedure is intended to provide a consistent approach to the management of Hydrofluoric acid (HF) across the University. Topics surrounding the management of HF covered by this document include training, purchasing, handling, storing, disposing and managing HF related emergencies.

HF Safety | Calgonate®

Dispose of unwanted hydrofluoric acid. When working with hydrofluoric acid or concentrated HF solutions (> 1%): Wear goggles and a face shield. Wear a long-sleeved, buttoned lab coat, pants or long skirt, and closed-toe shoes. Wear Neoprene or Nitrile (22mil) or other hydrofluoric acid resistant gloves.

Chemical Resistance of Gloves – Quick guide

Hexane nitrile (8 mil), double glove nitrile (35 mil or thicker), viton, PVA Hydrochloric Acid nitrile neoprene, butyl rubber Hydrofluoric Acid (HF) nitrile (8 mil), double glove Isopropanol nitrile Laser Dyes nitrile Lead Acetate nitrile, double glove Lead Salts nitrile Mercuric Chloride nitrile, double glove Mercury nitrile

Hydrofluoric Acid 40%

Hydrofluoric Acid 40% 1. Chemical Product and Company information. Product name: Hydrofluoric Acid, 40% Contact Information: Radchem cc PO Box 166982 Brackendowns Alberton 1454 Telephone : 011 867 3726 / 2864 2. Hazard Identification Very hazardous in case of skin contact (corrosive, irritant, permeator), of eye contact (irritant, corrosive), of

PPT – Hydrofluoric Acid Safety PowerPoint presentation ...

Title: Hydrofluoric Acid Safety 1 Hydrofluoric Acid Safety David Baird ESH Charlie Cooper Technical Division 2 Fatality Statistics . As little as 7 milliliters (ml) of anhydrous Hydrofluoric acid (HF) in contact with the skin untreated can bind all the free calcium in a normal size adult male. With burns involving greater than 25 square

Hydrofluoric acid 38 - 40% | VWR

Avantor ®, a Fortune 500 company, is a leading global provider of mission-critical products and services to customers in the biopharma, healthcare, education & government, and advanced technologies & applied materials industries.Our portfolio is used in virtually every stage of the most important research, development and production activities in the industries we serve.

Krynac 33110 F nitrile rubber bales | Sigma-Aldrich

Melting Point (°C) 0 - 100 (3) Application. detection (1) gas chromatography (GC) (1) HPLC (1) immunocytochemistry (1) immunohistochemistry (1) Species Reactivity. mouse (1) ... Plas-Labs nitrile glove box gloves. 1 Product Result | Match Criteria: Description ...

CHEMICAL RESISTANCE CHART

RESISTANCE CHART RATINGS — CHEMICAL EFFECT A — No effect—Excellent ... Acetic Acid, Glacia1 BA A CD B D Acetic Acid 20% BA A CD C Acetic Acid 80% BA AC DB C Acetic Acid B AA CDB C ... (NITRILE) Silicon Neoprene Ethylene Propylene …

HF Safety | Calgonate®

Dispose of unwanted hydrofluoric acid. When working with hydrofluoric acid or concentrated HF solutions (> 1%): Wear goggles and a face shield. Wear a long-sleeved, buttoned lab coat, pants or long skirt, and closed-toe shoes. Wear Neoprene or Nitrile (22mil) or other hydrofluoric acid resistant gloves.

Standard Operating Procedure (SOP) for the use of ...

Gloves: Medium or heavy weight viton/nitrile/natural rubber gloves (recommend 22 mil) should be worn as the outer glove when working with HF (note: double gloving should be considered as a Best Practice). For higher concentrations (>5%), long chemical compatible gloves (12 inches) should be worn. If outer gloves …

Rubber Chemical Resistance Chart, Rubber Compatibility ...

Welcome to our Rubber Chemical Resistance Chart. Here is the rubber compatibility chart that rates all popular rubber materials that comes into contact with various chemicals. Use this rubber chemical resistance chart to make sure that the elastomer or O-ring seal you choose will be compatible with the particular environment.

Gloves Chemical Resistance Chart | Gloves By Web

This chemical resistance chart is for advisory use only. Conditions, exposure times, chemical concentrations and residues may effect glove performance. It is strongly advised that on-site testing of all gloves is important to determining safe usage.

Chemical Safety Information-Hydrofluoric Acid ...

Gloves: Thin disposable gloves (such as 4, 6, or 8 mil blue Nitrile glove) used in laboratory operations provide a contact barrier only and should be disposed of immediately when contamination is suspected. Thicker (10-20 mil) PVC or neoprene gloves provide good resistance to HF but do not provide the necessary dexterity for most lab procedures.